Terminal units are the last piece of a central air conditioning system: they sit inside the conditioned zone, take in the air the system has prepared, and deliver it at the temperature, speed and direction the room needs. ROTER's terminal series covers three unit types, each addressing a different distribution problem.
The long-range jet air handling unit is a ceiling-mounted unit with cooling and heating functions and a manually adjustable spherical jet air diffuser as the supply outlet, which allows ductless long-distance air supply. The advantages are space saving, low engineering investment and low operating cost. The supply air angle can be adjusted freely within a 60° range, so cold and hot air reaches the designated air-conditioned zone rather than being wasted across the ceiling.
The cabinet-type air handling unit is an air treatment device for the terminal series of central air conditioning. The unit itself carries no cooling or heat source; chilled or hot water entering the heat exchanger exchanges heat with the indoor circulating air or with outdoor fresh air, performing cooling, heating, dehumidifying and drying, and filtration and purification. The treated air is then delivered through ductwork to the various air conditioning zones. It is available in ceiling-mounted, horizontal and vertical structures, and is widely used in air-conditioned spaces such as shopping malls, exhibition halls, theatres, hospitals, large factory buildings and high-rise buildings.
The fan coil unit consists mainly of a fan and a heat exchanger. Chilled or hot water entering the room passes through the heat exchanger and exchanges cooling or heating with the indoor air, regulating the indoor air temperature and humidity. Because of its efficiency and energy saving, quiet and comfortable operation, and space saving, the unit is available in horizontal concealed, horizontal exposed, vertical exposed and cassette types. When paired with fresh air units, it is widely used in hotels, shopping malls, offices, meeting rooms, hospitals and exhibition halls as the terminal device of central air conditioning systems.
| Unit | Choose it when | What to check |
|---|---|---|
| Long-range jet AHU | A large open floor needs air from a point, without ductwork running through the space | Throw distance, diffuser aim angle within 60°, and noise at the occupied zone |
| Cabinet-type AHU | The zone is served through ductwork and needs heating or cooling from a water circuit | Water flow and temperature drop across the coil, plus the mounting orientation |
| Fan coil unit | The room needs its own temperature and humidity control, typically alongside a fresh air unit | Coil capacity, air change rate, and whether concealed, exposed or cassette suits the ceiling |
Terminal units control temperature and humidity; they do not by themselves deliver fresh air. In most projects the terminal unit is paired with a fresh air unit from the Fresh Air System, so the room receives controlled outdoor air while the terminal unit handles the load. Specify both together and the fresh air volume should still be calculated from the per-person and air-change figures set out on that page.